| INPUT |
VOLTAGE(V) |
AC100~240V (AC85~264V or
DC120~370V), 50/60Hz (47~440Hz or DC) |
| CURRENT(A) |
100V ~1.0A,200V ~0.6A |
| FREQUENCY |
|
| EFFICIENCY |
70 % min |
| INRUSH CURRENT |
20A typ(AC IN 110V, Io=100%),40A
typ(AC IN 220V, Io=100%) at cold start |
| OUTPUT |
VOLTAGE(V) |
5 |
24 |
| CURRENT(A) |
0.6-3.0 |
0.2-0.7 |
| REGULATION,LINE(mV) |
±2 Max |
±10 Max |
| REGULATION,LOAD(mV) |
±2 Max |
±10 Max |
| RIPPLE(mVP-P) |
50 Max |
240 Max |
| RIPPLE,NOISE(mVP-P) |
100 Max |
290 Max |
| TEMPRETURE DRIFT,0~+50℃(mV) |
75 Max |
360 Max |
| RISE TIME(mS) |
1000 Max(AC IN 85V, Io=100%) |
| HOLDING TIME(mS) |
16 min (AC IN 85V, Io=100%) |
| PROTECTION CIRCUIT |
OVERCURRENT PROTECTION |
Works at over 110% of rating
and recovers automatically |
| OVERVOLTAGE PROTECTION |
Works at 115~140% of rating |
| ELECTRICALLY ISOLATED |
INPUT-OUTPUT |
AC 3,000V 1 minute current
20mA, DC 500V 100MΩ(At room temperature & Humidity) |
| INPUT-CASE,FG |
AC 2,000V 1 minute current
20mA, DC 500V 100MΩ(At room temperature & Humidity) |
| OUTPUT-CASE,CASE |
AC 500V 1 minute current
100mA, DC 500V 100MΩ(At room temperature & Humidity) |
| ENVIRONMENT |
OPERATING TEMP.AND HUMID. |
-10~+50℃, 20~90% RH(Non condensing) |
| STORAGE TEMP.AND HUMID. |
-20~+75℃, 20~90% RH(Non condensing) |
| VIBRATION |
10~55Hz at 1G, 3 minutes
period, 30 minutes along X,Y and Z axis |
| IMPACT |
10G for 20ms once on each
X,Y and Z axis |
| SAFETY |
SAFETY REGULATION |
UL,C-UL,CE |
| LINE CONDUCTED RF VOLTAGE |
Complied with FCC Part15
and EN55022 Class A Limits |
|
|
|
|
|